Effective stock management starts with reliable level measurement. König Brewery relies on KROHNE technology to measure the volumes of beer in its buffer tanks. Choosing the OPTIBAR 5060 eDP electronic differential pressure transmitter laid the foundations for a reliable solution that can be installed flexibly throughout the plant.

König Brewery, a subsidiary of the Bitburger Brewery Group, produces several types of beer in Duisburg. König Pilsener, named after its founder, remains the brewery’s flagship brand and one of Germany’s best-known beers. Since the end of 2020, König Brewery has been brewing carbon-neutrally. Residual emissions that are technically unavoidable (for now) are offset. The company is continually working to optimise its processes. The commissioning of a new pressure tank cellar in 2020 was part of these efforts. König Brewery planned and carried out the entire project itself.

The primary transmitter can even be mounted on top of the tank, where it is more accessible given the way the tanks are arranged.

Reliable level measurement for buffer tanks

The pressure tank cellar comprises 20 stainless steel cylindroconical tanks. These serve as buffer tanks for bottling. The tanks are up to 17 m high and have a capacity of 2,000 hl. The brewery needed reliable level measurement to manage its stocks. It initially considered conventional hydrostatic differential pressure measurement, but this proved impractical because of the tanks’ size and fill height. The difference in height between the two diaphragms would cause the pressure of the fill fluid in the capillary tube to drop below its vapour pressure, leading the liquid column to collapse. This effect limits the maximum length of capillaries mounted remotely from the fill fluid.

Electronic differential pressure transmitter

This is where KROHNE comes in. The OPTIBAR 5060 eDP electronic differential pressure transmitter offers a powerful and reliable alternative. It consists of two individual pressure transmitters connected by an electronic signal cable. The primary pressure transmitter measures the gas pressure at the top of the tank, while the secondary transmitter measures the pressure of the liquid column at the bottom, in a conical base. The secondary transmitter then sends the measured value to the primary transmitter, which calculates the net differential pressure from the two measurement signals. As this electronic differential pressure measurement system operates without capillary tubes, using an electrical signal instead, the height of the tanks at the plant poses no problem. Unlike conventional differential pressure measurement, it was also possible to install the system using significantly smaller process connections. This type of installation also allows the use of ceramic pressure transmitters and all their advantages.  

The OPTIBAR 5060 eDP electronic differential pressure transmitter offers a powerful and reliable alternative. It consists of two individual pressure transmitters connected by an electronic signal cable.

Tailored to requirements

The OPTIBAR 5060 eDP is fitted with a fully welded stainless steel diaphragm. The diaphragm welds are located outside the wetted sealing surface, so the process medium does not come into contact with the less corrosion-resistant weld, and there is no transition between the diaphragm material and the base material. This provides better protection against corrosion and leaks. The ceramic versions of this pressure transmitter contain no fill fluid. To meet the customer’s requirements, KROHNE equipped the OPTIBAR 5060 eDP with an electropolished stainless steel housing. The entire system is controlled via Profibus PA.

The OPTIBAR 5060 eDP electronic differential pressure transmitter offers a powerful and reliable alternative. It consists of two individual pressure transmitters connected by an electronic signal cable.

Reliable stock management

Using the OPTIBAR 5060 eDP helps ensure reliable management of the buffer beer volumes. The brewery operator monitors the buffer tanks via the control system, giving them a central overview of all available beer stocks. This enables the company to plan and make optimal use of its available buffer capacity. In this way, lengthy brewing processes, which can take several weeks, can be perfectly coordinated with fast bottling processes that take only a few hours. Compared with conventional differential pressure measurement using capillary tubes, electronic differential pressure measurement provided a highly reliable solution that can be installed flexibly throughout the plant. The primary transmitter could even be mounted on top of the tank, where it is more accessible given the way the tanks are arranged.

Complete package 

The OPTIBAR 5060 eDP is just one of the many process measurement instruments supplied by KROHNE to equip the beer cellar. The delivery also included electromagnetic flowmeters, temperature sensors and capacitive level switches. 

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeImproving production process reliability
  • SubjectSolutions
Share this article

Follow FoodTec Wallonie

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.