Measuring liquid chocolate levels
Texte et photos KROHNE

Chocolate is a real treat, but it presents challenges during production. It is inherently a viscous, sticky liquid that can build up on sensors used to monitor the process. When installing a new tank for pain au chocolat production, a French industrial bakery therefore opted from the outset for a sensor that could always guarantee reliable results, even under difficult conditions, to ensure perfect stock management. Naturally, the KROHNE Optiwave 3500 C.

A French industrial bakery produces pain au chocolat using liquid chocolate stored at 45°C in a 5 m-high tank with a conical top and bottom. Every four hours, a rotary scraper removes chocolate from the tank walls for 10 minutes. To ensure a constant supply of chocolate for production, the product level in the tank must be monitored continuously. The viscous, sticky liquid tends to build up, particularly on measurement probes that extend into the tank. As well as causing hygiene issues and higher maintenance costs, this can easily lead to inaccurate readings. The customer was also looking for an automated measurement solution to manage stock and reduce manual operations. As the tank was new, no measurement equipment had yet been installed.

The KROHNE solution
KROHNE installed the OPTIWAVE 3500 C. This 80 GHz FMCW radar level transmitter is designed for hygienic liquid applications. The radar sensor is installed with a DN51 SMS 1145 hygienic connection and a DN25 / 1.5″ flush-mounted PEEK lens antenna. Mounted on top of the tank, the device continuously measures the liquid chocolate level and automatically transmits the readings to the control room.

Benefits for the customer
KROHNE technology has enabled the customer to optimise the process while reducing maintenance and production costs.
The OPTIWAVE 3500 provides continuous, accurate measurements of the liquid chocolate level up to the process connection. Its flush-mounted PEEK lens antenna does not extend into the tank, preventing build-up and keeping maintenance costs low. Thanks to its very narrow beam angle, the radar can measure agitated product surfaces with an accuracy of ± 2 mm. The measured values are automatically transmitted to the control room. The solution is easy to install, commission and use, and delivers a rapid return.

Features of the Optiwave 3500 C
- 2-wire, 80 GHz FMCW non-contact radar level transmitter for liquids subject to hygienic requirements
- Flush-mounted PEEK lens antenna (no intrusion into the tank)
- Small dead zone and narrow beam angle
- Measuring range up to 50 m
- Suitable for cleaning in place (CIP) and sterilisation in place (SIP)
- Wide choice of hygienic process connections: clamps, SMS, DIN 11864-1, VARIVENT® …
- Accuracy of ± 2 mm; ± 0.08″.
- Process conditions up to 150 °C and 25 bar
- Quick setup wizard for easy commissioning
- Empty tank spectrum function to eliminate false reflections
- Large backlit LCD, 4-position keys and text display in 12 languages
- Free PACTwareTM DTM with full functionality.
Een zakelijke vraag aan KROHNE Belgium? Get in touch
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- ThemeImproving production process reliability
- SubjectSolutions
- CompanyKROHNE Belgium