Solutions

Safely starting or stopping hazardous machine movements

Le CKS2 d’Euchner est un nouveau système de serrure de sécurité qui peut être facilement intégré dans le système de commande global et utilisé pour une grande variété d’applications.
Le CKS2 d’Euchner est un nouveau système de serrure de sécurité qui peut être facilement intégré dans le système de commande global et utilisé pour une grande variété d’applications.

Safety tasks such as restricting access, safely locking and starting installations, or selecting the operating mode play an important role in modern installations. These tasks are often complex, but can be straightforward to solve. Euchner has therefore launched a new safety key system: the CKS2.  

Protecting people, machines and products is the guiding principle of the family-owned company Euchner, now led by Stefan Euchner, representing the third generation. As a specialist in industrial safety technology, the company develops and manufactures products and solutions tailored to the needs of customers across a wide range of sectors. Safety is also crucial in mechanical engineering and industrial automation. Safety technology is designed to protect people and machines, as well as improve production processes. The Automation, Safety and Human-Machine Interface product groups are increasingly interconnected in modern installations, while tasks are often becoming more complex. To ensure continuous safety, Euchner has launched a new key system: the CKS2. 

CKS2

Euchner’s CKS2 is a new safety key system that can be easily integrated into the overall control system and used for a wide range of applications. The CKS2 is also available as a submodule for the MGB2 Modular. This opens up many new applications for this door locking system.

In the MGB2 environment, the submodule is connected via PROFINET/PROFIsafe or EtherCAT/FSoE.

RFID keys with a high coding level

Hazardous machine movements often need to be started or stopped safely, independently of existing protective devices. The CKS2 is suitable for use as a lockout system, an authorisation system or a key transfer system. Thanks to the evaluation electronics integrated into the key unit, the system is compact and provides users with maximum safety through the use of RFID keys with a high coding level.  

One device, multiple functions

The new FlexFunction feature is the key to this versatility, and is very simple to use. Users define the system’s application during initial commissioning. They then select the right RFID key to activate exactly the device functions they need. Configuration takes place when the key is taught in for the first time. The key unit then has just one safety function to perform: reliably detecting the key. As soon as the key is recognised as valid, the safety outputs are activated. A key can also be assigned to multiple key units across different installations. 

Connection to IO-Link

Connection to IO-Link is also possible using the corresponding Euchner gateway. This can provide extended diagnostic and communication functions, such as identifying which key was used to operate the installation. With its versatile application options, the FlexFunction CKS2 device also offers additional benefits for logistics and ordering processes.

The key system for the MGB2 environment 

The key system can also be easily integrated into the MGB2 Modular as the MSM-CKS2 submodule. This further expands the range of applications for Euchner’s door locking system. New solutions are available, for example, for fully automated logistics systems or complete turnkey installations. This combination ensures efficient processes, provides flexibility in access rights, increases personnel and process safety, and delivers transparency and traceability.  

As the MSM-CKS2 submodule, the key system can also be easily integrated into the MGB2 Modular.

Modular design

By adding further safety modules to the MGB2, machine builders can incorporate a wide range of functions, including safety locking, emergency release, start/stop and emergency stop. The modular design also means that the MGB2 can eliminate the need for a separate control panel. 

Connection 

In the MGB2 environment, the submodule is connected via PROFINET/PROFIsafe or EtherCAT/FSoE. There is no complicated configuration or complex key management. The electronic operating principle means users can dispense with key exchange units and key distribution stations. Applications are defined directly in the control system, providing unlimited flexibility. 

Een zakelijke vraag aan EUCHNER? Get in touch