Clean, hygienic and accurate measurement, even with fluctuating densities

Measurements in the food industry must be clean, hygienic and accurate. Krohne offers a wide range of measuring systems, enabling it to provide the right system for every application. This article looks at two applications: a flowmeter in a CIP system and a mass flowmeter for measuring a non-conductive medium with continuously changing density.

A Turkish company develops and builds turnkey systems. It specialises in designing and manufacturing Cleaning-in-Place (CIP) cleaning machines, fully equipped with measurement technology. The CIP units comprise four lines that can be operated in parallel to carry out different cleaning processes simultaneously. The CIP media to be measured are fresh water, process water, acid and caustic. The company was looking for proven flowmeters to monitor the various cleaning agents.
Suitable for corrosive cleaning agents
One of the meter’s essential requirements was that it should also be suitable for corrosive cleaning agents such as acids and alkalis. The choice fell on Krohne’s OPTIFLUX 6050 C electromagnetic flowmeter. The meter’s standard PFA liner is suitable for the cleaning agents listed above. The flowmeter is also crevice-free and specially designed to remain clean and hygienic. To meet the customer’s specific process connection requirements, the instrument is fitted with a hygienic connection to DIN 11850 weld ends or DIN 11864-2.

How it works
The OPTIFLUX 6050 C monitors the actual flow rate and measures the total consumption in the various CIP lines. This enables the operator to adjust the dosing of each CIP medium accordingly. The right amount of cleaning agent is therefore always determined and added to ensure safe disinfection. This prevents both costly overdosing and under-supply to the CIP lines.
Cost-effective
The flowmeter is accurate enough for this straightforward application while also being cost-effective. It nevertheless remains stable over an extended period. It is maintenance-free and highly suitable for CIP media. Extensive digital communication is not required, as the CIP process is monitored using the amplifier’s simple analogue and pulse outputs.
Measuring the mass flow of a non-conductive medium
Krohne also has a solution for accurate measurements in animal fat with fluctuating densities. Here is one example. A waste-processing company specialising in animal by-products processes category 3 waste and slaughter by-products into high-quality protein meal and fats. For deliveries, the company needs accurate truck loading. Depending on its composition, the fat’s density can vary considerably during loading. The waste-processing company previously used a volumetric flowmeter. Because the instrument measured the loaded quantity by volume, it did not account for variations in density.

Coriolis mass flowmeter
The waste-processing company decided to replace the meter and chose an OPTIMASS 1400 F, the most economical mass flowmeter in its class on the market. This Coriolis mass flowmeter, with straight measuring tubes, was installed directly in the DN 50 line at the loading point. The meter is easy to install, with no modifications to the existing pipework required. In addition to mass flow, it measures density and temperature.
Setting the loading quantity
Krohne supplied its customer with a complete loading solution, including a preset counter connected to the OPTIMASS 1400, allowing the exact loading quantity to be set in advance. The company can now accurately determine the mass of the animal products during loading. The meter operates regardless of the medium’s conductivity and accounts for variations in density. This means there are no measurement errors during loading.
For more information:
www.krohne.com/nl/products/flow-measurement/flowmeters
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- ThemeFood safety from design to audit
- SubjectFood safety