What impact does the EU Regulation on food hygiene have on cabling? As a general rule, the fewer cables in high-risk zones, the better. In practice, however, reducing the number of cables to zero is impossible. Processing machinery needs at least a power supply. There are two principles to follow to achieve the highest possible level of hygiene: minimise the number of cables needed in your high-risk zones and use systems that can be cleaned thoroughly.
The General Regulation on food hygiene (EU/852/2004) states that food premises must be clean and well maintained. Their layout, design and construction must allow cleaning and/or disinfection to be carried out properly. In addition, surfaces in preparation areas where food is handled must be easy to clean. This means they must be made of smooth, washable, corrosion-
resistant and non-toxic materials, unless the operator can demonstrate that other materials are suitable.
Cabling subject to the same requirements
Surfaces that come into contact with food are of primary importance, but the authorities have explicitly imposed additional requirements on all surfaces in preparation areas where products could be contaminated by their surroundings. Every machine uses cabling to supply electrical and/or pneumatic power, as well as to receive and/or transmit electromagnetic signals and, today, of course, to carry data communications. Although this type of cabling does not come into direct contact with food, it is subject to the same requirements unless the operator can explicitly demonstrate that the solution currently in use is adequate. To meet the minimum requirements, the Hygienic Cabling Working Group within EHEDG has drawn up a practical guideline. Its main rule is: avoid cabling in preparation areas. If this is not possible, use only hygienic cabling. Hygienic cabling can be achieved by:
- minimising the number of cables by combining them in a fully enclosed cable protection conduit;
- using a simple system that can be cleaned thoroughly.
Points to consider
Various systems have appeared on the market in the past that ultimately proved not to meet minimum hygiene requirements.
- protective conduit split and cracked;
- cable glands damaged by cleaning agents;
- vertical cable support systems with too many cross-connections, making them difficult to clean thoroughly;
- cable ties that were difficult or impossible to clean on the back.
A new generation offers improved hygiene
The new generation of protective conduits, glands, cable fasteners and cable support systems has eliminated the hygiene problems of the past. Thanks to several suppliers, a complete range is now available for hygienic wet, controlled wet and dry cleaning of field and machine cabling. The new protective conduits are smooth and washable, and can no longer split, even when empty, thanks to their special spiral-shaped inner surface. The conduits no longer leak, are chemically resistant and are fitted with stainless steel connectors with a hygienic seal at the plug or box.