Solutions

Controlled atmosphere keeps fruit and vegetables fresher for longer

Appels, peren en dergelijke kunnen drie tot vier keer langer bewaard worden in CA / DCA-opslag dan onder normale omstandigheden.
Appels, peren en dergelijke kunnen drie tot vier keer langer bewaard worden in CA / DCA-opslag dan onder normale omstandigheden.

To offer seasonal fruit and vegetables all year round, they must be stored for several months in controlled atmosphere (CA) storage rooms. Humidity, temperature and CO2 sensors are crucial to ensuring the challenging conditions in these rooms are maintained. 

To ensure that fruit retains its texture, nutritional content, colour and flavour for as long as possible, it is stored in cold rooms at consistently low temperatures and high humidity. The composition of the storage atmosphere also has a significant effect on storage capacity. The ideal atmospheric composition for CA storage depends on the specific type of fruit or vegetable. Typical storage conditions are usually within the following ranges: < 2% O2 ; 0.5 - 5 °C; 0-5% CO2 and up to 98% RH. 

DCA storage

DCA storage technology, where DCA stands for Dynamic Controlled Atmosphere, is an improvement on conventional CA storage. It takes into account the fact that the stored fruit continuously releases heat, water, carbon dioxide and ethylene (C2H4) into the surrounding air through cellular respiration, changing the composition of the storage atmosphere. In DCA storage, oxygen levels and ethylene and carbon dioxide concentrations are therefore monitored continuously and controlled dynamically. The aim is to achieve the lowest possible oxygen level, just above the anaerobic compensation point (ACP), or the critical oxygen concentration at which fermentation occurs in the fruit's metabolic process.

CaTeC bv offers humidity, temperature and CO2 sensors from E+E Elektronik that are specially designed for use in demanding conditions.

Oxygen levels

In so-called Ultra Low Oxygen (ULO) or Extreme Low Oxygen (XLO) storage facilities, oxygen levels are gradually reduced to around 0.7 to 1%. This puts the stored fruit into a kind of ‘coma’ and reduces its metabolism to an absolute minimum. Variety-specific O2 and CO2 values must not be exceeded or exceeded during this process, otherwise the fruit will be damaged by a lack of oxygen or an excessively high CO2 concentration.  

Precise sensors 

To ensure ideal storage conditions, CA / DCA storage rooms are equipped with a wide range of technical systems for cooling, air conditioning, humidification and gas management. A prerequisite for precise control of storage conditions is continuous monitoring of the relevant climate parameters using suitable sensors. Reliable measuring equipment that delivers accurate readings is therefore essential. 

Measurement matters

Humidity, temperature and CO2 are among the most important parameters to monitor in CA / DCA storage. The challenging conditions in storage rooms give rise to the following sensor requirements: high measurement accuracy (<2% RH) and long-term stability in high-humidity conditions, a measurement principle resistant to contamination, ideally with automatic calibration, resistance to chemical contamination, resistance to condensation, a robust housing with an IP65 protection rating or higher, and easy maintenance and sensor replacement when servicing is required. 

To ensure ideal storage conditions, CA / DCA storage rooms are equipped with a wide range of technical systems for cooling, air conditioning, humidification and gas management.

EE211 and EE872 

CaTeC bv  offers humidity, temperature and CO2 sensors from E+E Elektronik that are specially designed for use in demanding conditions. Examples include the EE211 and EE872. The EE211 humidity and temperature sensor, for instance, features a heated humidity probe and a replaceable temperature probe. The combination of sealed electronics and E+E's unique sensor coating ensures high measurement accuracy, even in challenging ambient conditions. The EE872 CO2 probe, with its heated, easily replaceable sensor module, is particularly suitable for environments with high humidity and condensation. CO2 measurement is based on the contamination-resistant NDIR dual-wavelength principle and automatically compensates for ageing effects.    

Een zakelijke vraag aan CaTeC bv? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectSolutions
  • CompanyCaTeC bv
Share this article

Follow on FoodTec

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.